ATTENTION ATTENTION: Remember the Kp, Ki, Kd value the old fold what does not work properly there You are welcome to support me on my Amazon list: Thermal Runaway Protection: in cura on cooling and then note the initial fan speed if that is too high it could trigger the error Nozzel: M106 E0 S179 M303 E0 S250 C5 values M301 E0 Pxx.xx Ix.xx Dxx.xx M500 bed: M106 E0 S179 M303 E-1 S100 C5 M304 pxx.xx Ix.xx Dxx.xx M500 179 / 70 * 100 = 255 70% of 255 = approx 179 with original fan If something is wrong here the original values nozzel: Kp 15.94 Ki 1.17 Kd 54.19 With the new firmware, the component fan now turns faster and as long as you use the printer with the original Fan is operating, 70% should be the maximum. However, this leaves room for improvement if you swap the fan for a quieter one that does not achieve the desired performance at 70%. Firmware: Have fun shopping.
Concluzion: I3 mega PID Tuning /knutwurst/Thermal Runaway Protection – I3 mega,knutwusrt,firmware,pid,PID tuning,temperatur,anycubic,3d drucker,3D,Thermal Runaway Protection,octoprint,pronterface